Section 25.1391 14 CFR Ch. I (1-1-19 Edition) the minimum intensity prescribed in Section 25.1391 for the corresponding angles in the horizontal plane. (3) Intensities in overlaps between adjacent signals. No intensity in any overlap between adjacent signals may exceed the values given in Section 25.1395, except that higher intensities in overlaps may be used with main beam intensities substantially greater than the minima specified in SectionSection 25.1391 and 25.1393 if the overlap intensities in relation to the main beam intensities do not adversely affect signal clarity. When the peak intensity of the forward position lights is more than 100 candles, the maximum overlap intensities between them may exceed the values given in Section 25.1395 if the overlap intensity in Area A is not more than 10 percent of peak position light intensity and the overlap intensity in Area B is not greater than 2.5 percent of peak position light intensity. Section 25.1391 Minimum intensities in the horizontal plane of forward and rear position lights. Each position light intensity must equal or exceed the applicable values in the following table: Angle from right or left of longitudinal axis, measured from dead ahead Dihedral angle (light included) L and R (forward red and green). A (rear white) ..................... 0Section to 10Section .............. 10Section to 20Section ............ 20Section to 110Section .......... 110Section to 180Section ........ Intensity (candles) 40 30 5 20 Section 25.1393 Minimum intensities in any vertical plane of forward and rear position lights. Each position light intensity must equal or exceed the applicable values in the following table: spaschal on DSK3GDR082PROD with CFR Angle above or below the horizontal plane 0Section ......................................................................... 0Section to 5Section ................................................................ 5Section to 10Section .............................................................. 10Section to 15Section ............................................................ 15Section to 20Section ............................................................ 20Section to 30Section ............................................................ 30Section to 40Section ............................................................ 40Section to 90Section ............................................................ Intensity, l 1.00 0.90 0.80 0.70 0.50 0.30 0.10 0.05 Section 25.1395 Maximum intensities in overlapping beams of forward and rear position lights. No position light intensity may exceed the applicable values in the following table, except as provided in Section 25.1389(b)(3). Maximum intensity Overlaps Area A (candles) Green in dihedral angle L ............. Red in dihedral angle R ................ Green in dihedral angle A ............. Red in dihedral angle A ................ Rear white in dihedral angle L ...... Rear white in dihedral angle R ..... 10 10 5 5 5 5 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00362 Fmt 8010 1 1 1 1 1 1 Where - (a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and (b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees. Section 25.1397 Color specifications. Each position light color must have the applicable International Commission on Illumination chromaticity coordinates as follows: (a) Aviation red - y is not greater than 0.335; and z is not greater than 0.002. (b) Aviation green - x is not greater than 0.440Section0.320y ; x is not greater than ySection0.170; and y is not less than 0.390Section0.170x. (c) Aviation white - x is not less than 0.300 and not greater than 0.540; y is not less than xSection0.040; or y0Section0.010, whichever is the smaller; and y is not greater than x + 0.020 nor 0.636Section0.400x; Where y0 is the y coordinate of the Planckian radiator for the value of x considered. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-27, 36 FR 12972, July 10, 1971] 352 VerDate Sep<11>2014 Area B (candles) Sfmt 8010 Y:\SGML\247046.XXX 247046