Pt. 25, App. F 14 CFR Ch. I (1-1-19 Edition) (a) Criteria for Acceptance. (1) At least three specimens of cargo compartment sidewall or ceiling liner panels must be tested. (2) Each specimen tested must simulate the cargo compartment sidewall or ceiling liner panel, including any design features, such as joints, lamp assemblies, etc., the failure of which would affect the capability of the liner to safely contain a fire. (3) There must be no flame penetration of any specimen within 5 minutes after application of the flame source, and the peak temperature measured at 4 inches above the upper surface of the horizontal test sample must not exceed 400 SectionF. 402 VerDate Sep<11>2014 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00412 Fmt 8010 Sfmt 8002 Y:\SGML\247046.XXX 247046 EC28SE91.068 spaschal on DSK3GDR082PROD with CFR Part III - Test Method To Determine Flame Penetration Resistance of Cargo Compartment Liners.