Pt. 25, App. F 14 CFR Ch. I (1-1-19 Edition) spaschal on DSK3GDR082PROD with CFR (6) Turn off the burner and remove the thermocouple rake. (7) Repeat (1) to ensure that the burner is in the correct range. (g) Test Procedure. (1) Mount a thermocouple of the same type as that used for calibration at a distance of 4 inches (102 mm) above the horizontal (ceiling) test specimen. The thermocouple should be centered over the burner cone. (2) Mount the test specimen on the test stand shown in Figure 1 in either the horizontal or vertical position. Mount the insulating material in the other position. (3) Position the burner so that flames will not impinge on the specimen, turn the burner on, and allow it to run for 2 minutes. Rotate the burner to apply the flame to the specimen and simultaneously start the timing device. (4) Expose the test specimen to the flame for 5 minutes and then turn off the burner. The test may be terminated earlier if flame penetration is observed. (5) When testing ceiling liner panels, record the peak temperature measured 4 inches above the sample. (6) Record the time at which flame penetration occurs if applicable. (h) Test Report. The test report must include the following: (1) A complete description of the materials tested including type, manufacturer, thickness, and other appropriate data. (2) Observations of the behavior of the test specimens during flame exposure such as delamination, resin ignition, smoke, ect., including the time of such occurrence. (3) The time at which flame penetration occurs, if applicable, for each of the three specimens tested. (4) Panel orientation (ceiling or sidewall). 404 VerDate Sep<11>2014 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00414 Fmt 8010 Sfmt 8002 Y:\SGML\247046.XXX 247046