Federal Aviation Administration, DOT Pt. 25, App. F rimeter face. Ensure that the horizontal centerline of the burner cone is offset 1 inch below the horizontal centerline of the calorimeter (figure 8). Without disturbing the calorimeter position, rotate the burner in front of the thermocouple rake, such that the middle thermocouple (number 4 of 7) is centered on the burner cone. 441 VerDate Sep<11>2014 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00451 Fmt 8010 Sfmt 8006 Y:\SGML\247046.XXX 247046 ER31JY03.019 spaschal on DSK3GDR082PROD with CFR graduated cylinder for a 2-minute period. Determine the flow rate in gallons per hour. The fuel flow rate must be 6.0 Section0.2 gallons per hour (0.378 Section0.0126 L/min). (e) Calibration. (1) Position the burner in front of the calorimeter so that it is centered and the vertical plane of the burner cone exit is 4 Section0.125 inches (102 Section3 mm) from the calo-