Federal Aviation Administration, DOT Section 27.859 Section 27.831 Ventilation. (a) The ventilating system for the pilot and passenger compartments must be designed to prevent the presence of excessive quantities of fuel fumes and carbon monoxide. (b) The concentration of carbon monoxide may not exceed one part in 20,000 parts of air during forward flight or hovering in still air. If the concentration exceeds this value under other conditions, there must be suitable operating restrictions. (2) Fire resistant, in the case of other compartments. (b) No compartment may contain any controls, wiring, lines, equipment, or accessories whose damage or failure would affect safe operation, unless those items are protected so that - (1) They cannot be damaged by the movement of cargo in the compartment; and (2) Their breakage or failure will not create a fire hazard. Section 27.833 Heaters. Each combustion heater must be approved. (a) General. For each heating system that involves the passage of cabin air over, or close to, the exhaust manifold, there must be means to prevent carbon monoxide from entering any cabin or pilot compartment. (b) Heat exchangers. Each heat exchanger must be - (1) Of suitable materials; (2) Adequately cooled under all conditions; and (3) Easily disassembled for inspection. (c) Combustion heater fire protection. Except for heaters which incorporate designs to prevent hazards in the event of fuel leakage in the heater fuel system, fire within the ventilating air passage, or any other heater malfunction, each heater zone must incorporate the fire protection features of the applicable requirements of SectionSection 27.1183, 27.1185, 27.1189, 27.1191, and be provided with - (1) Approved, quick-acting fire detectors in numbers and locations ensuring prompt detection of fire in the heater region. (2) Fire extinguisher systems that provide at least one adequate discharge to all areas of the heater region. (3) Complete drainage of each part of each zone to minimize the hazards resulting from failure or malfunction of any component containing flammable fluids. The drainage means must be - (i) Effective under conditions expected to prevail when drainage is needed; and (ii) Arranged so that no discharged fluid will cause an additional fire hazard. (4) Ventilation, arranged so that no discharged vapors will cause an additional fire hazard. [Amdt. 27-23, 53 FR 34210, Sept. 2, 1988] FIRE PROTECTION Section 27.853 Compartment interiors. For each compartment to be used by the crew or passengers - (a) The materials must be at least flame-resistant; (b) [Reserved] (c) If smoking is to be prohibited, there must be a placard so stating, and if smoking is to be allowed - (1) There must be an adequate number of self-contained, removable ashtrays; and (2) Where the crew compartment is separated from the passenger compartment, there must be at least one illuminated sign (using either letters or symbols) notifying all passengers when smoking is prohibited. Signs which notify when smoking is prohibited must - (i) When illuminated, be legible to each passenger seated in the passenger cabin under all probable lighting conditions; and (ii) Be so constructed that the crew can turn the illumination on and off. spaschal on DSK3GDR082PROD with CFR [Amdt. 27-17, 45 FR 7755, Feb. 4, 1980, as amended by Amdt. 27-37, 64 FR 45095, Aug. 18, 1999] Section 27.855 Cargo and baggage compartments. (a) Each cargo and baggage compartment must be constructed of, or lined with, materials that are at least - (1) Flame resistant, in the case of compartments that are readily accessible to a crewmember in flight; and Section 27.859 Heating systems. 523 VerDate Sep<11>2014 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00533 Fmt 8010 Sfmt 8010 Y:\SGML\247046.XXX 247046