§ 27.859
(d)
Ventilating air ducts.
Each ven-
tilating air duct passing through any
heater region must be fireproof.
(1) Unless isolation is provided by
fireproof valves or by equally effective
means, the ventilating air duct down-
stream of each heater must be fireproof
for a distance great enough to ensure
that any fire originating in the heater
can be contained in the duct.
(2) Each part of any ventilating duct
passing through any region having a
flammable fluid system must be so
constructed or isolated from that sys-
tem that the malfunctioning of any
component of that system cannot in-
troduce flammable fluids or vapors
into the ventilating airstream.
(e)
Combustion air ducts.
Each com-
bustion air duct must be fireproof for a
distance great enough to prevent dam-
age from backfiring or reverse flame
propagation.
(1) No combustion air duct may con-
nect with the ventilating airstream un-
less flames from backfires or reverse
burning cannot enter the ventilating
airstream under any operating condi-
tion, including reverse flow or mal-
function of the heater or its associated
components.
(2) No combustion air duct may re-
strict the prompt relief of any backfire
that, if so restricted, could cause heat-
er failure.
(f)
Heater control: General.
There must
be means to prevent the hazardous ac-
cumulation of water or ice on or in any
heater control component, control sys-
tem tubing, or safety control.
(g)
Heater safety controls.
For each
combustion heater, safety control
means must be provided as follows:
(1) Means independent of the compo-
nents provided for the normal contin-
uous control of air temperature, air-
flow, and fuel flow must be provided for
each heater to automatically shut off
the ignition and fuel supply of that
heater at a point remote from that
heater when any of the following oc-
curs:
(i) The heat exchanger temperature
exceeds safe limits.
(ii) The ventilating air temperature
exceeds safe limits.
(iii) The combustion airflow becomes
inadequate for safe operation.
(iv) The ventilating airflow becomes
inadequate for safe operation.
(2) The means of complying with
paragraph (g)(1) of this section for any
individual heater must—
(i) Be independent of components
serving any other heater, the heat out-
put of which is essential for safe oper-
ation; and
(ii) Keep the heater off until re-
started by the crew.
(3) There must be means to warn the
crew when any heater, the heat output
of which is essential for safe operation,
has been shut off by the automatic
means prescribed in paragraph (g)(1) of
this section.
(h)
Air intakes.
Each combustion and
ventilating air intake must be located
so that no flammable fluids or vapors
can enter the heater system—
(1) During normal operation; or
(2) As a result of the malfunction of
any other component.
(i)
Heater exhaust.
Each heater ex-
haust system must meet the require-
ments of §§ 27.1121 and 27.1123.
(1) Each exhaust shroud must be
sealed so that no flammable fluids or
hazardous quantities of vapors can
reach the exhaust system through
joints.
(2) No exhaust system may restrict
the prompt relief of any backfire that,
if so restricted, could cause heater fail-
ure.
(j)
Heater fuel systems.
Each heater
fuel system must meet the powerplant
fuel system requirements affecting safe
heater operation. Each heater fuel sys-
tem component in the ventilating air-
stream must be protected by shrouds
so that no leakage from those compo-
nents can enter the ventilating air-
stream.
(k)
Drains.
There must be means for
safe drainage of any fuel that might ac-
cumulate in the combustion chamber
or the heat exchanger.
(1) Each part of any drain that oper-
ates at high temperatures must be pro-
tected in the same manner as heater
exhausts.
(2) Each drain must be protected
against hazardous ice accumulation
under any operating condition.
[Doc. No. 5074, 29 FR 15695, Nov. 24, 1964, as
amended by Amdt. 27–23, 53 FR 34211, Sept. 2,