Section 29.969 14 CFR Ch. I (1-1-19 Edition) (d) No rotorcraft skin immediately adjacent to a major air outlet from the engine compartment may act as the wall of an integral tank. [Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 29-26, 53 FR 34217, Sept. 2, 1988; Amdt. 29-35, 59 FR 50388, Oct. 3, 1994] Section 29.969 Fuel tank expansion space. Each fuel tank or each group of fuel tanks with interconnected vent systems must have an expansion space of not less than 2 percent of the combined tank capacity. It must be impossible to fill the fuel tank expansion space inadvertently with the rotorcraft in the normal ground attitude. [Amdt. 29-26, 53 FR 34217, Sept. 2, 1988] Section 29.971 Fuel tank sump. (a) Each fuel tank must have a sump with a capacity of not less than the greater of - (1) 0.10 per cent of the tank capacity; or (2) 1-16 gallon. (b) The capacity prescribed in paragraph (a) of this section must be effective with the rotorcraft in any normal attitude, and must be located so that the sump contents cannot escape through the tank outlet opening. (c) Each fuel tank must allow drainage of hazardous quantities of water from each part of the tank to the sump with the rotorcraft in any ground attitude to be expected in service. (d) Each fuel tank sump must have a drain that allows complete drainage of the sump on the ground. [Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as amended by Amdt. 29-12, 41 FR 55473, Dec. 20, 1976; Amdt. 29-26, 53 FR 34217, Sept. 2, 1988] spaschal on DSK3GDR082PROD with CFR Section 29.973 Fuel tank filler connection. (a) Each fuel tank filler connection must prevent the entrance of fuel into any part of the rotorcraft other than the tank itself during normal operations and must be crash resistant during a survivable impact in accordance with Section 29.952(c). In addition - (1) Each filler must be marked as prescribed in Section 29.1557(c)(1); (2) Each recessed filler connection that can retain any appreciable quantity of fuel must have a drain that dis- charges clear of the entire rotorcraft; and (3) Each filler cap must provide a fuel-tight seal under the fluid pressure expected in normal operation and in a survivable impact. (b) Each filler cap or filler cap cover must warn when the cap is not fully locked or seated on the filler connection. [Doc. No. 26352, 59 FR 50388, Oct. 3, 1994] Section 29.975 Fuel tank vents and carburetor vapor vents. (a) Fuel tank vents. Each fuel tank must be vented from the top part of the expansion space so that venting is effective under normal flight conditions. In addition - (1) The vents must be arranged to avoid stoppage by dirt or ice formation; (2) The vent arrangement must prevent siphoning of fuel during normal operation; (3) The venting capacity and vent pressure levels must maintain acceptable differences of pressure between the interior and exterior of the tank, during - (i) Normal flight operation; (ii) Maximum rate of ascent and descent; and (iii) Refueling and defueling (where applicable); (4) Airspaces of tanks with interconnected outlets must be interconnected; (5) There may be no point in any vent line where moisture can accumulate with the rotorcraft in the ground attitude or the level flight attitude, unless drainage is provided; (6) No vent or drainage provision may end at any point - (i) Where the discharge of fuel from the vent outlet would constitute a fire hazard; or (ii) From which fumes could enter personnel compartments; and (7) The venting system must be designed to minimize spillage of fuel through the vents to an ignition source in the event of a rollover during landing, ground operations, or a survivable impact. 636 VerDate Sep<11>2014 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00646 Fmt 8010 Sfmt 8010 Y:\SGML\247046.XXX 247046