652
14 CFR Ch. I (1–1–19 Edition)
§ 29.1199
fluid or fluid vapors into any personnel
compartment (due to leakage during
normal operation of the rotorcraft, or
discharge on the ground or in flight) is
prevented, even though a defect may
exist in the extinguishing system.
(Secs. 313(a), 601, and 603, 72 Stat. 759, 775, 49
U.S.C. 1354(a), 1421, and 1423; sec. 6(c), 49
U.S.C. 1655(c))
[Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as
amended by Amdt. 29–12, 41 FR 55473, Dec. 20,
1976; Amdt. 29–13, 42 FR 15047, Mar. 17, 1977]
§ 29.1199
Extinguishing agent con-
tainers.
(a) Each extinguishing agent con-
tainer must have a pressure relief to
prevent bursting of the container by
excessive internal pressures.
(b) The discharge end of each dis-
charge line from a pressure relief con-
nection must be located so that dis-
charge of the fire extinguishing agent
would not damage the rotorcraft. The
line must also be located or protected
to prevent clogging caused by ice or
other foreign matter.
(c) There must be a means for each
fire extinguishing agent container to
indicate that the container has dis-
charged or that the charging pressure
is below the established minimum nec-
essary for proper functioning.
(d) The temperature of each con-
tainer must be maintained, under in-
tended operating conditions, to prevent
the pressure in the container from—
(1) Falling below that necessary to
provide an adequate rate of discharge;
or
(2) Rising high enough to cause pre-
mature discharge.
(Secs. 313(a), 601, and 603, 72 Stat. 759, 775, 49
U.S.C. 1354(a), 1421, and 1423; sec. 6(c), 49
U.S.C. 1655 (c))
[Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as
amended by Amdt. 29–13, 42 FR 15047, Mar. 17,
1977]
§ 29.1201
Fire extinguishing system
materials.
(a) No materials in any fire extin-
guishing system may react chemically
with any extinguishing agent so as to
create a hazard.
(b) Each system component in an en-
gine compartment must be fireproof.
§ 29.1203
Fire detector systems.
(a) For each turbine engine powered
rotorcraft and Category A recipro-
cating engine powered rotorcraft, and
for each Category B reciprocating en-
gine powered rotorcraft with engines of
more than 900 cubic inches displace-
ment, there must be approved, quick-
acting fire detectors in designated fire
zones and in the combustor, turbine,
and tailpipe sections of turbine instal-
lations (whether or not such sections
are designated fire zones) in numbers
and locations ensuring prompt detec-
tion of fire in those zones.
(b) Each fire detector must be con-
structed and installed to withstand any
vibration, inertia, and other loads to
which it would be subjected in oper-
ation.
(c) No fire detector may be affected
by any oil, water, other fluids, or
fumes that might be present.
(d) There must be means to allow
crewmembers to check, in flight, the
functioning of each fire detector sys-
tem electrical circuit.
(e) The writing and other components
of each fire detector system in an en-
gine compartment must be at least fire
resistant.
(f) No fire detector system compo-
nent for any fire zone may pass
through another fire zone, unless—
(1) It is protected against the possi-
bility of false warnings resulting from
fires in zones through which it passes;
or
(2) The zones involved are simulta-
neously protected by the same detector
and extinguishing systems.
[Doc. No. 5084, 29 FR 16150, Dec. 3, 1964, as
amended by Amdt. 29–3, 33 FR 970, Jan. 26,
1968]
Subpart F—Equipment
G
ENERAL
§ 29.1301
Function and installation.
Each item of installed equipment
must—
(a) Be of a kind and design appro-
priate to its intended function;
(b) Be labeled as to its identification,
function, or operating limitations, or
any applicable combination of these
factors;
VerDate Sep<11>2014
12:50 Apr 30, 2019
Jkt 247046
PO 00000
Frm 00662
Fmt 8010
Sfmt 8010
Y:\SGML\247046.XXX
247046
spaschal on DSK3GDR082PROD with CFR