Pt. 36, App. A 14 CFR Ch. I (1-1-19 Edition) spaschal on DSK3GDR082PROD with CFR s-(24,k) = SPL-(24,k)SectionSPL-(23,k) s-(25,k) = s-(24,k) (f) Step 6: For i, from 3 through 23, compute the arithmetic average of the three adjacent slopes as follows: s(i,k) = 1-3[s-(i,k) + s-(i + 1,k) + s-(i + 2,k)] (g) Step 7: Compute final one-third octaveband sound pressure levels, SPL- (i,k), by beginning with band number 3 and proceeding to band number 24 as follows: SPL-(3,k) = SPL(3,k) SPL-(4,k) = SPL-(3,k) + s(3,k) - - SPL-(i,k) = SPL-(iSection1,k) + s(iSection1,k) - - SPL-(24,k) = SPL-(23,k) + s(23,k) (h) Setp 8: Calculate the differences, F (i,k), between the original sound pressure level and the final background sound pressure level as follows: F(i,k) = SPL(i,k)-SPL-(i,k) and note only values equal to or greater than 1.5. (i) Step 9: For each of the relevant onethird octave bands (3 through 24), determine tone correction factors from the sound pressure level differences F (i, k) and Table A36- 2. 786 VerDate Sep<11>2014 12:50 Apr 30, 2019 Jkt 247046 PO 00000 Frm 00796 Fmt 8010 Sfmt 8002 Y:\SGML\247046.XXX 247046