363
Federal Aviation Administration, DOT
Pt. 60, App. C
±
5 dB on three (3) consecu-
tive bands when compared
to initial evaluation; and
±
2
dB when comparing the av-
erage of the absolute dif-
ferences between initial
and continuing qualification
evaluation.
Applicable only to Continuing
Qualification Evaluations. If
frequency response plots
are provided for each
channel at the initial eval-
uation, these plots may be
repeated at the continuing
qualification evaluation with
the following tolerances ap-
plied:
(a) The continuing qualifica-
tion
1
⁄
3
octave band ampli-
tudes must not exceed
±
5
dB for three consecutive
bands when compared to
initial results.
(b) The average of the sum
of the absolute differences
between initial and con-
tinuing qualification results
must not exceed 2 dB
(refer to table C2C in Ap-
pendix C).
X Measurements are compared
to those taken during initial
qualification evaluation.
VerDate Sep<11>2014
16:30 Jun 25, 2019
Jkt 247047
PO 00000
Frm 00373
Fmt 8010
Sfmt 8002
Q:\14\14V2.TXT
PC31
kpayne on VMOFRWIN702 with $$_JOB