background image

454 

14 CFR Ch. I (1–1–19 Edition) 

Pt. 60, App. D 

T

ABLE

D2A—F

LIGHT

T

RAINING

D

EVICE

(FTD) O

BJECTIVE

T

ESTS

—Continued 

QPS requirements 

Information 

Test 

Tolerances 

Flight conditions 

Test details 

FTD level 

Notes 

Entry No. 

Title 

5 6 7 

4.f. .........................

Light point size ..............

Not greater than five (5) arc-min-

utes.

N/A ...........................

An SOC is required and must in-

clude the relevant calculations.

X  Light point size may be 

measured using a test 
pattern consisting of a 
centrally located single 
row of light points re-
duced in length until 
modulation is just dis-
cernible in each visual 
channel. A row of 48 
lights will form a 4

° 

angle 

or less. 

4.g. ........................

Light point contrast ratio 

.......................................................

...................................

.......................................................

A 1

° 

spot photometer may 

be used to measure a 
square of at least 1

° 

filled 

with light points (where 
light point modulation is 
just discernible) and 
compare the results to 
the measured adjacent 
background. During con-
trast ratio testing, simu-
lator aft-cab and flight 
deck ambient light levels 
should be zero. 

4.g.1. .....................

Reserved. 

4.g.2. .....................

........................................

Not less than 25:1 ........................

N/A ...........................

An SOC is required and must in-

clude the relevant calculations.

4.h. ........................

Visual ground segment. 

VerDate Sep<11>2014 

16:30 Jun 25, 2019

Jkt 247047

PO 00000

Frm 00464

Fmt 8010

Sfmt 8002

Q:\14\14V2.TXT

PC31

kpayne on VMOFRWIN702 with $$_JOB