Federal Aviation Administration, DOT Section 121.275 flight when there is a defect in the extinguishing system. If a methyl bromide system is used, the containers must be charged with dry agent and sealed by the fire-extinguisher manufacturer or some other person using satisfactory recharging equipment. If carbon dioxide is used, it must not be possible to discharge enough gas into the personnel compartments to create a danger of suffocating the occupants. make it possible for the crew to reopen the shutoff means after it has been closed. Section 121.259 Lines and fittings. (a) Each line, and its fittings, that is located in a designated fire zone, if it carries flammable fluids or gases under pressure, or is attached directly to the engine, or is subject to relative motion between components (except lines and fittings forming an integral part of the engine), must be flexible and fire-resistant with fire-resistant, factoryfixed, detachable, or other approved fire-resistant ends. (b) Lines and fittings that are not subject to pressure or to relative motion between components must be of fire-resistant materials. Section 121.267 Extinguishing agent container pressure relief. Extinguishing agent containers must be provided with a pressure relief to prevent bursting of the container because of excessive internal pressures. The discharge line from the relief connection must terminate outside the airplane in a place convenient for inspection on the ground. An indicator must be provided at the discharge end of the line to provide a visual indication when the container has discharged. Section 121.261 Vent and drain lines. All vent and drain lines and their fittings, that are located in a designated fire zone must, if they carry flammable fluids or gases, comply with Section 121.259, if the Administrator finds that the rupture or breakage of any vent or drain line may result in a fire hazard. Section 121.269 Extinguishing agent container compartment temperature. Precautions must be taken to insure that the extinguishing agent containers are installed in places where reasonable temperatures can be maintained for effective use of the extinguishing system. Section 121.263 Fire-extinguishing systems. (a) Unless the certificate holder shows that equivalent protection against destruction of the airplane in case of fire is provided by the use of fireproof materials in the nacelle and other components that would be subjected to flame, fire-extinguishing systems must be provided to serve all designated fire zones. (b) Materials in the fire-extinguishing system must not react chemically with the extinguishing agent so as to be a hazard. Section 121.271 Fire-extinguishing system materials. (a) Except as provided in paragraph (b) of this section, each component of a fire-extinguishing system that is in a designated fire zone must be made of fireproof materials. (b) Connections that are subject to relative motion between components of the airplane must be made of flexible materials that are at least fire-resistant and be located so as to minimize the probability of failure. Section 121.265 Fire-extinguishing agents. Only methyl bromide, carbon dioxide, or another agent that has been shown to provide equivalent extinguishing action may be used as a fire-extinguishing agent. If methyl bromide or any other toxic extinguishing agent is used, provisions must be made to prevent harmful concentrations of fluid or fluid vapors from entering any personnel compartment either because of leakage during normal operation of the airplane or because of discharging the fire extinguisher on the ground or in Section 121.273 Fire-detector systems. Enough quick-acting fire detectors must be provided in each designated fire zone to assure the detection of any fire that may occur in that zone. Section 121.275 Fire detectors. Fire detectors must be made and installed in a manner that assures their 99 VerDate Sep<11>2014 08:20 May 17, 2019 Jkt 247048 PO 00000 Frm 00109 Fmt 8010 Sfmt 8010 Y:\SGML\247048.XXX 247048