839
Federal Aviation Administration, DOT
§ 171.275
(iii) The station power emission and
frequencies of the ISMLS localizer,
glide path, beacon markers, and associ-
ated compass locators, if any.
(iv) The hours of operation.
(v) Station identification call letters
and method of station identification
and the time spacing of the identifica-
tion.
(vi) A description of the critical parts
that may not be changed, adjusted, or
repaired without an FAA flight check
to confirm published operations.
(d) The owner or his maintenance
representative must make a ground
check of the ISMLS facility periodi-
cally in accordance with procedures ap-
proved by the FAA at the time of com-
missioning, and must report the results
of the checks as provided in § 171.275.
(e) Modifications to an ISMLS facil-
ity may be made only after approval by
the FAA of the proposed modification
submitted by the owner.
(f) The owner or the owner’s mainte-
nance representative must participate
in inspections made by the FAA.
(g) Whenever it is required by the
FAA, the owner must incorporate im-
provements in ISMLS maintenance.
(h) The owner or his maintenance
representative must provide a suffi-
cient stock of spare parts, including
solid state components, or modules to
make possible the prompt replacement
of components or modules that fail or
deteriorate in service.
(i) FAA approved test instruments
must be used for maintenance of the
ISMLS facility.
(j) The mean corrective maintenance
time of the ISMLS equipment may not
exceed 0.5 hours, with a maximum cor-
rective maintenance time of not great-
er than 1.5 hours. This measure applies
to failures of the monitor, transmitter
and associated antenna assemblies,
limited to unscheduled outage and out-
of-tolerance conditions.
(k) The mean time between failures
of the ISMLS equipment may not be
less than 1,500 hours. This measure ap-
plies to unscheduled outages, out-of-
tolerance conditions, and failures of
the monitor, transmitter, and associ-
ated antenna assemblies.
(l) Inspection consists of an examina-
tion of the ISMLS equipment to ensure
that unsafe operating conditions do not
exist.
(m) Monitoring of the ISMLS radi-
ated signal must ensure a high degree
of integrity and minimize the require-
ments for ground and flight inspection.
The monitor must be checked periodi-
cally during the in-service test evalua-
tion period for calibration and sta-
bility. These tests and ground checks
of glide slope, localizer, and marker
beacon radiation characteristics must
be conducted in accordance with the
maintenance requirements of this sec-
tion.
§ 171.275
Reports.
The owner of the ISMLS facility or
his maintenance representative must
make the following reports at the indi-
cated time to the appropriate FAA Re-
gional Office where the facility is lo-
cated.
(a)
Facility Equipment Performance and
Adjustment Data
(
FAA Form 198
). The
FAA Form 198 shall be filled out by the
owner or his maintenance representa-
tive with the equipment adjustments
and meter readings as of the time of fa-
cility commissioning. One copy must
be kept in the permanent records of the
facility and two copies must be sent to
the appropriate FAA Regional Office.
The owner or his maintenance rep-
resentative must revise the FAA Form
198 data after any major repair, mod-
ernization, or retuning to reflect an ac-
curate record of facility operation and
adjustment. In the event the data are
revised, the owner or his maintenance
representative shall notify the appro-
priate FAA Regional Office of such re-
visions, and forward copies of the revi-
sions to the appropriate FAA Regional
Office.
(b)
Facility Maintenance Log
(
FAA
Form 6030
–
1
). FAA Form 6030–1 is a per-
manent record of all the activities re-
quired to maintain the ISMLS facility.
The entries must include all malfunc-
tions met in maintaining the facility
including information on the kind of
work and adjustments made, equip-
ment failures, causes (if determined)
and corrective action taken. In addi-
tion, the entries must include comple-
tion of periodic maintenance required
to maintain the facility. The owner or
his maintenance representative must
VerDate Sep<11>2014
08:20 May 17, 2019
Jkt 247048
PO 00000
Frm 00849
Fmt 8010
Sfmt 8010
Y:\SGML\247048.XXX
247048