Section 171.13 Section 171.13 14 CFR Ch. I (1-1-19 Edition) Subpart B - Nondirectional Radio Beacon Facilities Reports. The owner of each facility to which this subpart applies shall make the following reports on forms furnished by the FAA, at the times indicated, to the FAA Regional office for the area in which the facility is located: (a) Record of meter readings and adjustments (Form FAA-198). To be filled out by the owner with the equipment adjustments and meter readings as of the time of commissioning, with one copy to be kept in the permanent records of the facility and two copies to the appropriate Regional office of the FAA. The owner shall revise the form after any major repair, modernization, or returning, to reflect an accurate record of facility operation and adjustment. (b) Facility maintenance log (FAA Form 6003-1). This form is a permanent record of all equipment malfunctioning met in maintaining the facility, including information on the kind of work and adjustments made, equipment failures, causes (if determined), and corrective action taken. The owner shall keep the original of each report at the facility and send a copy to the appropriate Regional office of the FAA at the end of the month in which it is prepared. (c) Radio equipment operation record (Form FAA-418). To contain a complete record of meter readings, recorded on each scheduled visit to the facility. The owner shall keep the original of each month-s record at the facility and send a copy of it to the appropriate Regional office of the FAA. (d) [Reserved] (e) VOR ground check error data (Forms FAA-2396 and 2397). To contain results of the monthly course accuracy ground check in accordance with FAA Handbook AF P 6790.9 - Maintenance Instructions for VHF Omniranges - . The owner shall keep the originals in the facility and send a copy of each form to the appropriate Regional office of the FAA on a monthly basis. (49 U.S.C. 1348) [Doc. No. 5034, 29 FR 11337, Aug. 6, 1964, as amended by Amdt. 171-5, 34 FR 15245, Sept. 30, 1969; Amdt. 171-10, 40 FR 36110, Aug. 19, 1975] Section 171.21 Scope. (a) This subpart sets forth minimum requirements for the approval and operation of non-Federal, nondirectional radio beacon facilities that are to be involved in the approval of instrument flight rules and air traffic control procedures related to those facilities. (b) A nondirectional radio beacon ( - H - facilities domestically - NDB facilities internationally) radiates a continuous carrier of approximately equal intensity at all azimuths. The carrier is modulated at 1020 cycles per second for station identification purposes. [Doc. No. 5034, 29 FR 11337, Aug. 6, 1964, as amended by Amdt. 171-2, 31 FR 5408, Apr. 6, 1966; Amdt. 171-7, 35 FR 12711, Aug. 11, 1970] Section 171.23 Requests for IFR procedure. (a) Each person who requests an IFR procedure based on a nondirectional radio beacon facility that he owns must submit the following information with that request: (1) A description of the facility and evidence that the equipment meets the performance requirements of Section 171.27 and is installed in accordance with Section 171.29. (2) A proposed procedure for operating the facility. (3) A proposed maintenance arrangement and a maintenance manual that meets the requirements of Section 171.31. (4) A statement of intention to meet the requirements of this subpart. (5) A showing that the facility has an acceptable level of operational reliability and an acceptable standard of performance. Previous equivalent operational experience with a facility with identical design and operational characteristics will be considered in showing compliance with this subparagraph. (b) After the FAA inspects and evaluates the facility, it advises the owner of the results and of any required changes in the facility or the maintenance manual or maintenance organization. The owner must then correct the deficiencies, if any, and operate the 808 VerDate Sep<11>2014 08:20 May 17, 2019 Jkt 247048 PO 00000 Frm 00818 Fmt 8010 Sfmt 8010 Y:\SGML\247048.XXX 247048