Pipeline and Haz. Matls. Safety Admin., DOT be visually inspected in accordance with CGA pamphlet, CGA C-6 (incorporated by reference, see Section 171.7). A current copy of CGA pamphlet, CGA C-6 must be available at the facility servicing the life-saving appliance. b. An installed inflation cylinder that requires recharging must be filled in accordance with Section 173.301(l). c. Every installed inflation cylinder, as associated equipment of the life-saving appliance, must be packed within the protective packaging of the life raft and the life raft itself must otherwise be in compliance with Section 173.219. d. The serial number for each cylinder must be recorded as part of the life-saving appliance service record by the U.S. Coast Guard-approved servicing facility. 340 This entry applies only to the vessel transportation of nickel-metal hydride batteries as cargo. Nickel-metal hydride button cells or nickel-metal hydride cells or batteries packed with or contained in battery-powered devices transported by vessel are not subject to the requirements of this special provision. See - Batteries, dry, sealed, n.o.s. - in the Section 172.101 Hazardous Materials Table (HMT) of this part for transportation requirements for nickelmetal hydride batteries transported by other modes and for nickel-metal hydride button cells or nickel-metal hydride cells or batteries packed with or contained in battery-powered devices transported by vessel. Nickel-metal hydride batteries subject to this special provision are subject only to the following requirements: (1) The batteries must be prepared and packaged for transport in a manner to prevent a dangerous evolution of heat, short circuits, and damage to terminals; and are subject to the incident reporting in accordance with Section 171.16 of this subchapter if a fire, violent rupture, explosion or dangerous evolution of heat (i.e., an amount of heat sufficient to be dangerous to packaging or personal safety to include charring of packaging, melting of packaging, scorching of packaging, or other evidence) occurs as a direct result of a nickel metal hydride battery; and (2) when loaded in a cargo transport unit in a total quantity of 100 kg gross mass or more, the shipping paper requirements of Subpart C of this part, the manifest requirements of Section 176.30 of this subchapter, and the vessel stowage requirements assigned to this entry in Column (10) of the Section 172.101 Hazardous Materials Table. 342 Glass inner packagings (such as ampoules or capsules) intended only for use in sterilization devices, when containing less than 30 mL of ethylene oxide per inner packaging with not more than 300 mL per outer packaging, may be transported in accordance with Section 173.4a of this subchapter, irre- Section 172.102 spective of the restriction of Section 173.4a(b) and the indication of - forbidden - in columns (9A) and (9B) of the Section 172.101 table provided that: a. After filling, each glass inner packaging must be determined to be leak-tight by placing the glass inner packaging in a hot water bath at a temperature and for a period of time sufficient to ensure that an internal pressure equal to the vapor pressure of ethylene oxide at 55 SectionC is achieved. Any glass inner packaging showing evidence of leakage, distortion or other defect under this test must not be transported under the terms of this special provision; b. In addition to the packaging required in Section 173.4a, each glass inner packaging must be placed in a sealed plastic bag compatible with ethylene oxide and capable of containing the contents in the event of breakage or leakage of the glass inner packaging; and c. Each glass inner packaging is protected by a means of preventing puncture of the plastic bag (e.g., sleeves or cushioning) in the event of damage to the packaging (e.g., by crushing). 343 A bulk packaging that emits hydrogen sulfide in sufficient concentration that vapors evolved from the crude oil can present an inhalation hazard must be marked as specified in Section 172.327of this part. 345 - Nitrogen, refrigerated liquid (cryogenic liquid), UN1977 - transported in open cryogenic receptacles with a maximum capacity of 1 L are not subject to the requirements of this subchapter. The receptacles must be constructed with glass double walls having the space between the walls vacuum insulated and each receptacle must be transported in an outer packaging with sufficient cushioning and absorbent materials to protect the receptacle from damage. 346 - Nitrogen, refrigerated liquid (cryogenic liquid), UN1977 - transported in accordance with the requirements for open cryogenic receptacles in Section 173.320 and this special provision are not subject to any other requirements of this subchapter. The receptacle must contain no hazardous materials other than the liquid nitrogen which must be fully absorbed in a porous material in the receptacle. 347 Effective July 1, 2011, for transportation by aircraft, this entry may only be used if the results of Test series 6(d) of Part I of the UN Manual of Tests and Criteria (IBR, see Section 171.7 of this subchapter) have demonstrated that any hazardous effects from accidental functioning are confined to within the package. Effective January 1, 2012, for transportation by vessel, this entry may only be used if the results of Test Series 6(d) of Part I of the UN Manual of Tests and Criteria (IBR, see Section 171.7 of this 355 VerDate Sep<11>2014 16:41 Oct 31, 2018 Jkt 244226 PO 00000 Frm 00365 Fmt 8010 Sfmt 8010 Q:\49\49V2.TXT PC31