Previous Page | Page 495 | Next Page |
486
14 CFR Ch. I (1–1–14 Edition)
§ 25.1101
for the applicable altitude and oper-
ating condition because of super-
charging.
[Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as
amended by Amdt. 25–38, 41 FR 55467, Dec. 20,
1976; Amdt. 25–40, 42 FR 15043, Mar. 17, 1977;
Amdt. 25–57, 49 FR 6849, Feb. 23, 1984; Amdt.
25–72, 55 FR 29785, July 20, 1990]
§ 25.1101
Carburetor air preheater de-
sign.
Each carburetor air preheater must
be designed and constructed to—
(a) Ensure ventilation of the pre-
heater when the engine is operated in
cold air;
(b) Allow inspection of the exhaust
manifold parts that it surrounds; and
(c) Allow inspection of critical parts
of the preheater itself.
§ 25.1103
Induction system ducts and
air duct systems.
(a) Each induction system duct up-
stream of the first stage of the engine
supercharger and of the auxiliary
power unit compressor must have a
drain to prevent the hazardous accu-
mulation of fuel and moisture in the
ground attitude. No drain may dis-
charge where it might cause a fire haz-
ard.
(b) Each induction system duct must
be—
(1) Strong enough to prevent induc-
tion system failures resulting from
normal backfire conditions; and
(2) Fire-resistant if it is in any fire
zone for which a fire-extinguishing sys-
tem is required, except that ducts for
auxiliary power units must be fireproof
within the auxiliary power unit fire
zone.
(c) Each duct connected to compo-
nents between which relative motion
could exist must have means for flexi-
bility.
(d) For turbine engine and auxiliary
power unit bleed air duct systems, no
hazard may result if a duct failure oc-
curs at any point between the air duct
source and the airplane unit served by
the air.
(e) Each auxiliary power unit induc-
tion system duct must be fireproof for
a sufficient distance upstream of the
auxiliary power unit compartment to
prevent hot gas reverse flow from burn-
ing through auxiliary power unit ducts
and entering any other compartment
or area of the airplane in which a haz-
ard would be created resulting from the
entry of hot gases. The materials used
to form the remainder of the induction
system duct and plenum chamber of
the auxiliary power unit must be capa-
ble of resisting the maximum heat con-
ditions likely to occur.
(f) Each auxiliary power unit induc-
tion system duct must be constructed
of materials that will not absorb or
trap hazardous quantities of flammable
fluids that could be ignited in the
event of a surge or reverse flow condi-
tion.
[Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as
amended by Amdt. 25–46, 43 FR 50597, Oct. 30,
1978]
§ 25.1105
Induction system screens.
If induction system screens are
used—
(a) Each screen must be upstream of
the carburetor;
(b) No screen may be in any part of
the induction system that is the only
passage through which air can reach
the engine, unless it can be deiced by
heated air;
(c) No screen may be deiced by alco-
hol alone; and
(d) It must be impossible for fuel to
strike any screen.
§ 25.1107
Inter-coolers and after-cool-
ers.
Each inter-cooler and after-cooler
must be able to withstand any vibra-
tion, inertia, and air pressure load to
which it would be subjected in oper-
ation.
E
XHAUST
S
YSTEM
§ 25.1121
General.
For powerplant and auxiliary power
unit installations the following apply:
(a) Each exhaust system must ensure
safe disposal of exhaust gases without
fire hazard or carbon monoxide con-
tamination in any personnel compart-
ment. For test purposes, any accept-
able carbon monoxide detection meth-
od may be used to show the absence of
carbon monoxide.
(b) Each exhaust system part with a
surface hot enough to ignite flammable
fluids or vapors must be located or
VerDate Mar<15>2010
10:12 Mar 18, 2014
Jkt 232046
PO 00000
Frm 00496
Fmt 8010
Sfmt 8010
Y:\SGML\232046.XXX
232046
pmangrum on DSK3VPTVN1PROD with CFR
Previous Page | Page 495 | Next Page |