Federal Aviation Administration, DOT 

§ 25.1801 

(b) No EWIS component of any fire or 

overheat detector system for any fire 
zone may pass through another fire 
zone, unless: 

(1) It is protected against the possi-

bility of false warnings resulting from 
fires in zones through which it passes; 
or 

(2) Each zone involved is simulta-

neously protected by the same detector 
and extinguishing system. 

(c) EWIS that are part of each fire or 

overheat detector system in a fire zone 
must meet the requirements of 
§ 25.1203. 

§ 25.1733

Fire detector systems, gen-

eral: EWIS. 

EWIS associated with any installed 

fire protection system, including those 

required by §§ 25.854 and 25.858, must be 
considered an integral part of the sys-
tem in showing compliance with the 
applicable requirements for that sys-
tem. 

Subpart I—Special Federal 

Aviation Regulations 

S

OURCE

: Docket No. FAA–2011–0186, Amdt. 

25–133, 76 FR 12555, Mar. 8, 2011, unless other-
wise noted. 

§ 25.1801

SFAR No. 111—Lavatory Oxy-

gen Systems. 

The requirements of § 121.1500 of this 

chapter also apply to this part. 