(b) No EWIS component of any fire or
overheat detector system for any fire
zone may pass through another fire
zone, unless:
(1) It is protected against the possi-
bility of false warnings resulting from
fires in zones through which it passes;
or
(2) Each zone involved is simulta-
neously protected by the same detector
and extinguishing system.
(c) EWIS that are part of each fire or
overheat detector system in a fire zone
must meet the requirements of
§ 25.1203.
§ 25.1733
Fire detector systems, gen-
eral: EWIS.
EWIS associated with any installed
fire protection system, including those
required by §§ 25.854 and 25.858, must be
considered an integral part of the sys-
tem in showing compliance with the
applicable requirements for that sys-
tem.