Previous Page | Page 576 | Next Page |
567
Federal Aviation Administration, DOT
Pt. 25, App. F
(1) Description of the specimen.
(2) Radiant heat flux to the specimen, ex-
pressed in W/cm
2
.
(3) Data giving release rates of heat (in kW/
m
2
) as a function of time, either graphically
or tabulated at intervals no greater than 10
seconds. The calibration factor (k
n
) must be
recorded.
(4) If melting, sagging, delaminating, or
other behavior that affects the exposed sur-
face area or the mode of burning occurs,
these behaviors must be reported, together
with the time at which such behaviors were
observed.
(5) The peak heat release and the 2-minute
integrated heat release rate must be re-
ported.
VerDate Mar<15>2010
10:12 Mar 18, 2014
Jkt 232046
PO 00000
Frm 00577
Fmt 8010
Sfmt 8002
Y:\SGML\232046.XXX
232046
pmangrum on DSK3VPTVN1PROD with CFR
Previous Page | Page 576 | Next Page |