Previous Page | Page 344 | Next Page |
334
14 CFR Ch. I (1–1–14 Edition)
Pt. 60, App. D
T
ABLE
D2A—F
LIGHT
T
RAINING
D
EVICE
(FTD) O
BJECTIVE
T
ESTS
—Continued
QPS requirements
Information
Test
Tolerances
Flight conditions
Test details
FTD level
Notes
Entry No.
Title
5 6 7
4.f.
.........................
Light
point
size
..............
Not greater than five (5) arc-min-
utes.
N/A
...........................
An SOC is required and must in-
clude the relevant calculations.
X
Light point size may be
measured using a test
pattern consisting of a
centrally located single
row of light points re-
duced in length until
modulation is just dis-
cernible in each visual
channel. A row of 48
lights will form a 4
°
angle
or less.
4.g.
........................
Light point contrast ratio
.......................................................
.................
..................
.......................................................
A 1
°
spot photometer may
be used to measure a
square of at least 1
°
filled
with light points (where
light point modulation is
just discernible) and
compare the results to
the measured adjacent
background. During con-
trast ratio testing, simu-
lator aft-cab and flight
deck ambient light levels
should be zero.
4.g.1.
.....................
Reserved.
4.g.2.
.....................
........................................
Not less than 25:1
........................
N/A
...............
............
An SOC is required and must in-
clude the relevant calculations.
X
4.h.
........................
Visual ground segment.
VerDate Mar<15>2010
20:48 Jan 30, 2014
Jkt 232047
PO 00000
Frm 00344
Fmt 8010
Sfmt 8002
Q:\14\14V2.TXT
ofr150
PsN: PC150
Previous Page | Page 344 | Next Page |